Search

Chia Lei Ang

from Avon, IN
Age ~38

Chia Ang Phones & Addresses

  • Avon, IN
  • Indianapolis, IN
  • West Lafayette, IN
  • Danville, IN
  • W Lafayette, IN
  • 6116 N Meridian St #W, Indianapolis, IN 46208 (317) 408-6109

Work

Position: Building and Grounds Cleaning and Maintenance Occupations

Education

Degree: Bachelor's degree or higher

Publications

Us Patents

System For Improved Tissue-Handling And In Line Analysis Of The Tissue

View page
US Patent:
20130231585, Sep 5, 2013
Filed:
Nov 24, 2011
Appl. No.:
13/383318
Inventors:
Jacob Flagle - New Palestine IN, US
Chia Yee Ang - Avon IN, US
Kenneth F. DeFreitas - Patterson NY, US
Ian Shaw - Yorktown Heights NY, US
John LaViola - Range CT, US
Samantha Perkins - Avon IN, US
Zachary R. Nicoson - Zionsville IN, US
Assignee:
HOLOGIC INC. - Bedford MA
International Classification:
A61B 6/00
A61B 10/02
US Classification:
600565
Abstract:
A system for analysis of biopsy samples includes a tissue sample transport mechanism linking a biopsy sample excision tool to a tissue sample holder disposed in a staging area of an analysis unit. The tissue sample is automatically transported from the excision tool to the specimen holder, where the tissue sample is analyzed in the staging area of the analysis unit. The transport mechanism may include tubing and a vacuum source. The tissue sample holder may be configured to slow or temporarily stop a tissue sample for individual analysis, or collect multiple tissue samples for analysis as a group. A tissue sample sorting mechanism may be employed that allows separation of specimens that can be correlated to the analysis.

System For Improved Tissue Handling And In Line Analysis Of The Tissue

View page
US Patent:
20190346471, Nov 14, 2019
Filed:
Mar 14, 2019
Appl. No.:
16/353705
Inventors:
- Marlborough MA, US
Chia Yee Ang - Avon IN, US
Kenneth F. Defrietas - Patterson NY, US
Ian Shaw - Yorktown Heights NY, US
John Laviola - Range CT, US
Samantha Perkins - Avon IN, US
Zachary R. Nicoson - Zionsville IN, US
Assignee:
Hologic, Inc. - Marlborough MA
International Classification:
G01N 35/04
A61B 10/00
A61B 10/02
B01L 3/00
A61B 6/00
Abstract:
A system for analysis of biopsy samples includes a tissue sample transport mechanism linking a biopsy sample excision tool to a tissue sample holder disposed in a staging area of an analysis unit. The tissue sample is automatically transported from the excision tool to the specimen holder, where the tissue sample is analyzed in the staging area of the analysis unit. The transport mechanism may include tubing and a vacuum source. The tissue sample holder may be configured to slow or temporarily stop a tissue sample for individual analysis, or collect multiple tissue samples for analysis as a group. A tissue sample sorting mechanism may be employed that allows separation of specimens that can be correlated to the analysis.

System For Improved Tissue Handling And In Line Analysis Of The Tissue

View page
US Patent:
20170131311, May 11, 2017
Filed:
Jan 19, 2017
Appl. No.:
15/410669
Inventors:
- Marlborough MA, US
Chia Yee ANG - Avon IN, US
Kenneth F. DEFRIETAS - Patterson NY, US
Ian SHAW - Yorktown Heights NY, US
John LAVIOLA - Orange CT, US
Samantha PERKINS - Avon IN, US
Zachary R. NICOSON - Zionsville IN, US
International Classification:
G01N 35/04
B01L 3/00
A61B 6/00
A61B 10/00
A61B 10/02
Abstract:
A system for analysis of biopsy samples includes a tissue sample transport mechanism linking a biopsy sample excision tool to a tissue sample holder disposed in a staging area of an analysis unit. The tissue sample is automatically transported from the excision tool to the specimen holder, where the tissue sample is analyzed in the staging area of the analysis unit. The transport mechanism may include tubing and a vacuum source. The tissue sample holder may be configured to slow or temporarily stop a tissue sample for individual analysis, or collect multiple tissue samples for analysis as a group. A tissue sample sorting mechanism may be employed that allows separation of specimens that can be correlated to the analysis.
Chia Lei Ang from Avon, IN, age ~38 Get Report